ÇöÀçÀ§Ä¡ : HOME > PRODUCT> CompactPCI> 6U System Platform
8U Rackmount 9-Slot High Density Server Chassis
Standard 6U CompactPCI form factor
9-slot backplane for stand-alone system board or compute blade
Built-in 400W AC-input dual redundant power supply
One 3.5" and three 5.25" drive bays
Alarm module for monitoring chassis temperature and fan status
Switch, drive bays and redundant power supply are protected by door
Redundant cooling architecture
Designed for NEBS Level 3 installation
9U Rack Mount Subsystem with Redundant Power Module
Dimensions 482.6(W) x 354.8(H) x 365(D) mm ( w/o handle)
CompactPCI Standards 2.0 R3.0, 2.1 R2.0
Form Factor 6U cPCI with 80mm depth rear I/O
Enclosure EIA RS-310C 19" 8U high rack-mount enclosure
Coated metal plate outer covering
Switch, drive bays and redundant power supply are protected by door
Basic Alarm Module Monitoring inner chassis temperature, fan status
Abnormal status will generate alarm and LED warning
Alarm reset (silence of beeper)
LED indications show power voltage status on 5V, 3.3V, 12V and -12V
Cooling System Front-access hot-swappable fan tray for ventilation:
12V DC brush-less, dual ball bearing
Two blower-fans for ventilation with 25.2 CFM/each.
Rated speed for each fan: 2500 ¡¾ 250 RPM
Rated power for each fan: 7.8W
Removable fans on the bottom for in-take:
12V DC brush-less, dual ball bearing
Two fans for in-take with 49.5 CFM/each
Rated speed for each fan: 2700 ¡¾ 300 RPM
Rated power for each fan: 2.5W
Rear-access removable fan for drive bays and power supply:
12V DC brush-less, dual ball bearing
One 90 CFM fan for ventilation
Rated speed for each fan: 3100 ¡¾ 250 RPM
Rated power for each fan: 4.8W
Disk Drive Bays One 3.5" and three 5.25" drive bays
Passive Backplane ELK-cBP-6309: 9-system-slot 6U cPCI Backplane with RIO
Power Supply
Dual Redundant 400W power supply with cooling fan
AC Input 90~264VAC universal input, 47~63Hz, and Active PFC: >0.95
DC Output
(400W Single Module)
45A @ +5V, 28A @ +3.3V, 20A @ +12V, 1A @ -12V
(+5Vsb and -5V are not used in cPCI system)
Maximum total output for +5V and +3.3V: 250W
Efficiency: 63% at 115V, full load
Protection Over load protection: 105% ~ 150%
Over temperature protection: 95¢ªC
Short circuit protection: each voltage output
Power fail alarm: if one power module fails or turns off,
the buzzer will beep.
Fan fail alarm: if power fan fails or turns, the buzzer will beep
De-rating De-rating temperature: 45¢ªC
De-rating 20¢ªC to 70¢ªC
Safety or
Certificate
UL 60950: 2000
CSA22.2 No.60950: 2000
TUV EN-60950: 1997
IEC 60950: 1996
EMKO-TSE 207/94
FCC part 15 Class B
EN 50081-1 (EN 55022 Class B, EN 61000-3-2 Class D,
EN 61000-3-3)
CNS 13438 CLASS B
EN 50082-1 (EN 61000-4-2~6,8,11)
Weight 33.1 Kg (including 400W redundant power supply and backplane)
NEBS Design for NEBS Level 3
Environmental
Operating Non-Operating
Temperature 0 to 55¡ÆC -20 to 80¡ÆC
Humidity 5 - 95% @ 40¡ÆC non-condensing 0 - 95% @ 40¡ÆC non-condensing
Shock 15G peak-to-peak, 11ms duration, non-operation
Vibration 0.5Grms, 5-500Hz, each axis, test with 2.5" HDD 1.88Grms, 5-500Hz, each axis
Altitude 15,000 ft. (4,572 m) 50,000 ft. (15,240 m)
Redundant security blade include Firewall/VPN/IDS/Traffic Management High availability mission critical applications
High performance technical computing for scientific or image processing HLR/VLR and Multimedia on demand (MOD)
ISP/Enterprise HA web/Email hosting/ Application Server  
ELK-cPCI3100BLS 6U cPCI 8U Rackmount 9-Slot High Density Server Chassis with Door and 400W Dual Redundant PSU, FDD, CD-ROM and HDD Rack (w/o HDD)
All specifications within this document are subject to change without notice.